Máy quang phổ hồng ngoại Spectrum 3 Mid-IR được thiết kế theo tiêu chuẩn vàng ISO-9001. Hệ giao thoa DynascanTM được cấp bằng sáng chế Thiết kế ổn định, không cần căn chỉnh động học để bù cho bất kỳ những thay đổi thường có mặt trong hệ thống giao thoa sử dụng gương di động. Bộ phận giao thoa với thiết kế đơn giản giúp tăng tuổi thọ và độ tin cậy Variable J-Stop: Điều chỉnh ...
 
Model: R-300 Manufacturer: BUCHI- Switzerland
 
Model: R-100 Manufacturer: BUCHI- Switzerland
 
PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.
 
PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.
 
PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.
 
LAMBDA 365 delivers state-of-the-art UV/Vis performance that meets the needs of pharmaceuticals, analytic chemists, geneticists, and manufacturing QA/QC analysts everywhere.
 
The semi-automatic Abel closed cup tester measures the flash point, the lowest temperature at which the vapors of a sample ignite upon the application of an ignition source. AB 5 is suitable for volatility applications of petroleum products, solvents, chemicals, fluxed bitumen, etc.
 
The automatic Cleveland Open Cup (COC) measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning. CLA 5 is suitable for the application range of volatility, lubricants, residual fuels or bituminous material.
 
The DU 4 is designed for examining the boiling range characteristics of petroleum products as well as aromatic hydrocarbons and other volatile organic liquids.
 
The automatic Pensky-Martens closed cup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. PMA 5 is suitable for volatility applications of both biodiesel and biodiesel-blended fuels along with distillate fuels like diesel, heating oil and kerosene. It is commonly used for potentially flammable liquids such as lubricating oils and edible oils, too.
 
Monowave 450 is a modern microwave reactor specially designed for microwave-assisted extractions in analytical laboratories. Its 24-position autosampler MAS24 for 30 mL Wide-Neck vials provides unattended reliable operation and increases the sample throughput. The integrated camera allows watching on the touchscreen what is going on inside the vial any time.
 
ADU 5 is the ideal solution to automatically perform high-precision atmospheric distillation tests to characterize the volatility of petrochemical products like all standard fuels, biodiesel and ethanol-blended gasoline.
 
The DMTA system consists of a rheometer combined with the convection temperature devices CTD 450 and CTD 600 and a large variety of fixtures such as solid circular or rectangular fixtures, film and fiber fixtures or parallel-plate systems.
 
The new MCR xx2 series is based on technical concepts at the cutting edge of technology. The EC motor technique, the low friction bearing and the patented normal force sensor have been optimized over years to satisfy the highest demands of rheologists. Any type or combination of rheological tests, both in rotational and oscillatory mode, are possible with the MCR rheometers. The modularity of the system allows the integration of a wide range of temperature devices and application-specific ...
 
The Multiwave PRO platform serves two groups: professionals in synthetic chemistry and trace analysis. This brochure focuses on the use of Multiwave PRO as a microwave reaction system for parallel synthesis. Multiwave PRO serves method development or a large instrument for the multigram scale. You can upgrade the system to cover different scales at any time by just adding rotors. The combination of sealed vessel technology with reaction conditions beyond the boiling point of the applied solvent ...
 
Based on a revolutionary new technique, the all-new Masterwave BTR benchtop reactor for the first time transfers microwave synthesis to the kilolab. Productivity in your lab is considerably increased up to kilogram amounts per day. The benchtop reactor’s magnetically driven paddle stirrer provides independent stirring regimes for individual content. Due its rising-sensor temperature measurement technique, Masterwave BTR features the high temperature accuracy required for direct method transfer ...
 
The semi-automatic OBA 2 safety tester is used to determine the oxidation stability (induction period) and the tendency to formgum (potential residue) under accelerated oxidation conditions. It complies with German safety regulations to avoid health hazards caused by unexpected explosions. OBA 2 is suitable for oxidation stability applications of gasoline and aviation fuel.
 
PNR 12 automatically measures the resistance a material provides to being pierced by a specifically shaped penetrator. The harder the test material, the more pointed and needle-like the penetrator should be. The penetrometer is used for consistency and plasticity determination of pasty, creamy, semi-solid or highly viscous samples.
 
The automatic breaking point tester determines the brittle behavior of bitumen at low temperatures. The Fraass breaking point is the temperature at which the first crack appears in the coating of a thin, flat steel plaque, flexed under descending temperatures.
 
The semi-automatic RCRT with its gas-free furnace indicates coke-forming properties by determining the amount of carbon residue left after evaporation and pyrolysis of an oil sample. It is applicable to relatively non-volatile petroleum products, which partially decompose on distillation at atmospheric pressure, like diesel fuel, motor oil, gas or crude oil.
 
The automatic DDA 3 force-ductility meter offers three procedures to measure bitumen properties: Ductility or elongation is measured by the distance to which a sample will elongate before breaking. Elastic recovery is measured by the recoverable strain determined after severing an elongated briquette specimen. This is useful in confirming that a material has been added to the asphalt to provide a significant elastomeric characteristic. Force-ductility measures tensile properties and the ...
 
Gum content is the residue of aircraft fuels, motor gasoline and other volatile distillates which cannot be evaporated. Fuel samples of 50 mL are evaporated under controlled temperature conditions and the flow of air or steam
 
The DH 5 is a Herschel emulsifier that serves to measure the ability of petroleum oils or synthetic fluids to separate from water.
 
The ring-and-ball softening point tester automatically determines the temperature at which a substance attains a particular degree of softness. It is used for samples without sharply defined melting points, which become softer and less viscous as the temperature rises. The RKA 5 with its different ball-centering and dispensing devices is suitable for bitumen, waxes, adhesives, resins, polymers, road-marking materials and sealing compounds.
 
The fully automated, compact, stand-alone CFPP tester Callisto 100 determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. Callisto 100 comes with a newly developed state-of-the-art Peltier element concept which allows the connection of a methanol-free cooling system. It ensures outstanding homogeneity of the cooling jacket, which is the most critical and decisive parameter for a correct CFPP value determination
 
The Multiwave PRO microwave reaction system delivers the high-quality solutions you need to obtain excellent trace analysis results, even with complicated, demanding samples. Multiwave PRO masters high temperatures and provides comprehensive safety features. Its wide range of accessories allows digestion, leaching, oxygen combustion, solvent extraction, drying, evaporation, and UV digestion with one single system.
 
The Beer Monitor from Anton Paar is a highly accurate instrument for continuously monitoring the alcohol content, apparent and real extract, original extract, degree of fermentation, density, and temperature of your beer, alcoholic mixtures, and alcohol-free beer. To achieve maximum accuracy, even when the CO2 content fluctuates, the Beer Monitor can be connected to a CO2 meter from the Carbo series. This is a very efficient solution for additional CO2 measurements and compensation of the ...
 
The Alcohol Monitor determines the alcohol content of your alcohol/water mixtures in the range from 0 to 100 % (v/v,w/w) at 0 °C to 40 °C. The alcohol content can be given as %v/v or %w/w. It consists of Density Transducer DPRn 427 (I) and mPDS 1100 (I) or mPDS 5 Evaluation Unit. The Alcohol Monitor is highly accurate, drift-free and requires no maintenance. Anton Paar's oscillating U-tube method is the the most accurate method for online density measurement. The Alcohol Monitor is installed ...
 
The Online Brix Monitor is for highly accurate online Brix measurement in the full range of 0 to 90 °Brix and 0 to 100 °C. It continuously determines the Brix valule of soft drinks, fruit juice and syrup. The Online Brix Monitor accurately monitors your Brix values, whether you use HFCS, cane sugar or beet sugar. The °Brix concentration is determined by measuring the resonance frequency of a U-tube density meter DPRn 427 (I) combined with mPDS 1100 or mPDS 5 Evaluation Unit. The system ...
 
The Soft Drink Analyzer M density and sound velocity meter determines the density and sound velocity of your soft drink, syrup or HFCS sample in one cycle. The combination of Soft Drink Analyzer M and the Plug and Play sample changer, Xsample 122, allows you to monitor the sugar inversion process with the highest precision. Due to its state-of-the-art user interface design, Soft Drink Analyzer M provides unparalleled ease of use. It also guarantees complete transparency and traceability of the ...
 
The PBA-S Generation M (Packaged Beverage Analyzer for Soft Drinks) is the up-to-date measuring system for beverage analysis. Determine sugar (°Brix) and CO2 in soft drinks without prior sample degassing. The beverage is filled into the analysis system directly from its container and is then measured within three minutes: °Brix and CO2 content are determined in a single work step. The modular system consists of the DMA 4100/4500/5000 M density meter, the CarboQC ME CO2 measuring module, and ...
 
New functional and ergonomic design based on the innovative CVi-TECH philosophy invented by CONTROLS * Advanced electronics technologies providing superior performances and total flexibility combined with simplicity in use * Double interface: large size 4,3" touch screen color display and PC * With PC software VICASOFT-PREMIUM (optional) up to 32 indipendent units can be connected to a single PC via LAN port and hub * All units are remotely controlled * Integrated graphic printer is available as ...
 
The AxION 2 TOF MS instrument is available with a choice of patented ion sources including dual probe Ultraspray™ 2 ESI or Field-Free Atmospheric Pressure Chemical Ionization (APCI). With its exact mass capabilities, AxION 2 TOF MS is the ideal tool for identification of unexpected compounds in your samples, providing a high level of resolution and mass accuracy -- consistently, day after day. The wide dynamic range allows accurate isotopic ratio and quantitation capabilities over a wide range ...
 
Verify. Quantify. Simplify. Designed for HPLC and UHPLC applications, the Flexar™ SQ 300 MS is the ideal detection solution for analysts seeking a fast, accurate and powerful analytical system to make their labs and workflows more efficient and productive. It's the ideal solution to identify, confirm and quantify compounds with complete confidence.
 
Sensitivity. Stability. Versatility. Introducing the new Clarus® SQ 8 Gas Chromatograph/Mass Spectrometer (GC/MS). This world-class system delivers uncompromised performance with consistent ultra-trace detection limits consistenly and reliably – time after time.
 
Sensitivity. Stability. Versatility. Introducing the new Clarus® SQ 8 Gas Chromatograph/Mass Spectrometer (GC/MS). This world-class system delivers uncompromised performance with consistent ultra-trace detection limits consistenly and reliably – time after time.
 
Sensitivity. Stability. Versatility. Introducing the new Clarus® SQ 8 Gas Chromatograph/Mass Spectrometer (GC/MS). This world-class system delivers uncompromised performance with consistent ultra-trace detection limits consistenly and reliably – time after time.
 
The Atomx XYZ Automated Purge and Trap VOC sample preparation system is designed for versatility and function. As the only combined automation/concentrator platform on the market today, it is also the only system capable of automated methanol extractions for high-level soils in accordance with USEPA Method 5035. Reaching beyond previous benchmarks, the system includes improved moisture control, a precision-machined valve manifold, reduced overall system footprint, increased 84 VOA vial capacity ...
 
Anton Paar presents a high-temperature Ultra Nanoindentation Tester (UNHT3 HTV) for measuring mechanical properties at elevated temperatures Anton Paar announces the launch of the UNHT3 HTV, the nanoindentation device designed for testing at temperatures up to 800 °C, based on Anton Paar’s longstanding experience in nanoindentation testing. The heart of the UNHT3 HTV is based on the highly successful and patented Ultra Nanoindentation Tester (UNHT). The measurement head has been optimized ...
 
The 3200 QTRAP® LC/MS/MS System provides excellent sensitivity, superior dynamic range, and reliability across a range of identification and quantitation applications. With features found in our industry-leading LC/MS/MS systems, the 3200 QTRAP® System brings true hybrid triple quadrupole/linear ion trap capabilities within the reach of any lab.
 
Measuring Resistivity, IP and SP * High reliability, safety and robustness under harsh field conditions *Easy to use with multi-lingual graphical user interface on sunlight readable colour LCD * On-site capabilities for data QA, system diagnostics and fault tolerance * Superior quality in data acquisition with powerful transmitter and high dynamic range multi-channel receiver.
 
The density meter DMA 5000 M provides unparalleled ease of use and complete transparency and traceability of the sample filling and measurement process. DMA 5000 M is the most accurate density meter on the market and is ideal for numerous applications. Digital density measurement with DMA 5000M is used, for example, in industrial quality control, research, at authorities and standards organizations The new Generation M density meters combine the DMAs’ known excellent measuring capabilities ...
 
The SVM 3000 Stabinger Viscometer measures the dynamic viscosity and density of oils and fuels according to ASTM D7042. From this result, the viscometer automatically calculates the kinematic viscosity and delivers measurement results which are equivalent to ISO 3104 or ASTM D445. The Stabinger measuring principle with Peltier thermostat enables an incomparably wide viscosity and temperature range with a single system. SVM 3000 is quick, compact and energy-saving, versatile in use, with only ...
 
MCP 300/500 Sucromat is the state-of-the-art saccharimeter providing highly accurate analysis of °Z (International Sugar Scale) for the sugar industry. While MCP 300 measures at 589 nm, MCP 500 measures at two wavelengths: 589 nm and 880 nm. At 880 nm MCP 500 can measure strongly colored filtrates which cannot be measured in the visible range. Over 30 years of experience and highest quality in development, production and customer support has made Anton Paar saccharimeters the standard in sugar ...
 
Precise beer analysis guarantees the high quality of your beer. The Alcolyzer Beer ME Analyzing System is a highly accurate beer analysis system which determines the alcohol content of all types of beers, beer mixtures, ciders, etc. The patented NIR measuring method eliminates the influence of other sample constituents on the alcohol measurement and therefore guarantees highly precise results. When combined with a density meter, Alcolyzer Beer ME determines further parameters in a single cycle, ...
 
Engineered to deliver a level of stability, flexibility and performance never before seen in an ICP-MS instrument, the NexION™ 350 represents the first truly significant and revolutionary industry advancement in recent memory. For the first time ever, a single ICP-MS instrument offers both the simplicity and convenience of a collision cell and the exceptional detection limits of a true reaction cell. With this patented Universal Cell Technology™ (UCT), analysts can now ...
 
Headspace Gas Chromatography—for applications involving the solvent-free extraction of volatile compounds, it’s an unsurpassed technique, eliminating the time-consuming steps and risk of human error associated with other GC sample-preparation methods. Engineered to deliver unparalleled precision, sensitivity and productivity in a broad range of specialized applications—including forensics, food and beverage, pharmaceuticals and environmental—TurboMatrix™ Headspace (HS) and Headspace ...
 
Fully automatic test cycle - The complete test cycle is automatically performed by simply pressing the start button (both via display and via software) - PC control option - Accuracy Class 1 (EN) and Class A (ASTM) - Adopt the latest ES Energy Saving technologies. For reduction of power consumption and silent operation - Connect to laboratory network via LAN port/software
 
The complete test cycle is automatically performed by simply pressing the start button (both via display and via software). Correct test execution according to selected Standards, is continuously and automatically controlled. Adopt the latest ES Energy Saving technologies. Allowing high throughput of accurate tests (up to 40 per hour). Double frame standard control and third frame control option. Connect to laboratory network via LAN port. Allow remote verification of settings and ...
 
Fully automatic test cycle - The complete test cycle is automatically performed by simply pressing the start button (both via display and via software) - Correct test execution according to selected Standards, is continuously and automatically controlled - Double user interface based on display and PC - Accuracy Class 1 (EN) and Class A (ASTM) starting from 10% of full scale - Adopt the latest ES Energy Saving technologies - Double stage hydraulic pump with rapid approach and precise oil flow ...
 
ABEM Terrameter LUND Imaging System is an Automatic System for Resistivity and IP Imaging, designed for optimum versatility in infrastructure projects and environmental studies * Built-in quality control and feedback to operator * Automated roll-along capability for 2D and 3D surveys * High productivity rate thanks to speed-optimised software (particularly in 4 channel version).
 
Engineered to deliver a level of stability, flexibility and performance never before seen in an ICP-MS instrument, the NexION™ 350 represents the first truly significant and revolutionary industry advancement in recent memory. For the first time ever, a single ICP-MS instrument offers both the simplicity and convenience of a collision cell and the exceptional detection limits of a true reaction cell. With this patented Universal Cell Technology™ (UCT), analysts can now choose the most ...
 
Automatic test cycle * Correct test execution according to selected Standards, is continuously and automatically controlled. See additional information * Dual user interface display and PC * Accuracy Class 1 (EN) and Class A (ASTM) starting from 10% of full scale. Special calibration starting from 3kN for 300kN chamber and from 0.5kN for 15kN available on request * Compatible with the new, intuitive and smart DATA MANAGER Software * Adopt the latest ES Energy Saving technologies * Allowing high ...
 
Automatic test cycle - Correct test execution according to selected Standards, is continuously and automatically controlled - Dual user interface display and PC - Accuracy Class 1 (EN) and Class A (ASTM) starting from 10% of full scale - Compatible with the new, intuitive and smart DATA MANAGER Software - Very easy to use, complete with many functions, totally flexible, open to network comunications Adopt the latest ES Energy Saving technologies. For reduction of power consumption and silent ...
 
Engineered to deliver a level of stability, flexibility and performance never before seen in an ICP-MS instrument, the NexION™ 350 represents the first truly significant and revolutionary industry advancement in recent memory. For the first time ever, a single ICP-MS instrument offers both the simplicity and convenience of a collision cell and the exceptional detection limits of a true reaction cell. With this patented Universal Cell Technology™ (UCT), analysts can now choose the most ...
 
-DMA 35 is the new generation of Anton Paar portable density meters, using the oscillating U-tube technology. DMA 35 measures the density and concentrations of your sample and shows the measuring results within seconds on the large display, ready for storage, printout or export to a PC. Its robust and lightweight design enables the use in numerous fields of application and its on-site operation in a wide range of work environments. This basic model enables the manual selection of measuring ...