AUTOMATIC VICAT APPARATUS Automatic setting time tester for cement, mortar and gypsum
EN 196-3 | EN 480-2 | ASTM C191 | AASHTO T131
MAIN FEATURES
New functional and ergonomic design based on the innovative CVi-TECH philosophy invented by CONTROLS througt the recent years
Advanced electronics technologies providing superior performances and total flexibility combined with simplicity in use
Easy-to-use double interface: local mode, with large size 4,3" touch screen color display, and remote mode, with PC
Supplied complete with PC software for data processing VICASOFT-BASIC
With PC software VICASOFT-PREMIUM (optional) up to 32 indipendent units can be connected to a single PC via LAN port and hub. All units are remotely controlled. Adopting the multi-test network concept laboratory productivity is maximized
Integrated graphic printer is available as optional accessory showing both results in numerical format and setting time plot
Easy setting and storage of user-defined test profiles allowing quick test start
Large accessibility to the test space
Practical in-water testing accessory (optional)
Automatic determination of initial and final setting time
GENERAL DESCRIPTION
CONTROLS have long tradition in manufacturing automatic setting time testers for cement and mortar. A new generation, the third one, is now available. The new machine has been completely redesigned based on the innovative CVI-TECH philosophy. As with the older generations the test procedure is unchanged, a needle (or a probe) drops freely into a cement sample at regular intervals and in fixed positions. Penetration depth is measured by a sensor with 0,1 mm resolution. Along with hardening process development the penetration depth decreases, when it matches some thresholds pre-defined by Standards initial and final setting times are measured and recorded.
ORDERING INFORMATION
63-L2700/E
VICAMATIC-2, automatic electronic apparatus for setting time test on cement/mortar/gypsum. Complete with EN 196-3 accessories: initial setting time needle 1.13 mm dia., mould and PC software VICASOFT-BASIC.
230V, 50-60Hz, 1ph.
63-L2700/EZ
Same as above, but 110V, 60Hz, 1 Ph.
63-L2700/F
VICAMATIC-2, automatic electronic apparatus for setting time test on cement/mortar/gypsum. Complete with ASTM C191 accessories: initial setting time needle 1.00 mm dia., mould and PC software VICASOFT-BASIC.
230V, 50-60Hz, 1ph.
63-L2700/FZ
Same as above, but 110V, 60Hz, 1 Ph.
63-L2700
VICAMATIC-2, automatic electronic apparatus for setting time test on cement/mortar/gypsum complete with PC software VICASOFT-BASIC. Supplied without accessories.
230V, 50-60Hz, 1ph.
63-L2700/Z
Same as above, but 110V, 60Hz, 1 Ph.
ACCESSORIES
63-L2700/E10
Accessory for needle cleaning and in-water testing
63-L2700/E11
LAN hub for PC connection of up to 7 VICAMATIC-2 units or up to 6 units in case of multi-hub network. LAN cable from hub to PC is included. Each VICAMATIC-2 unit is supplied complete with LAN cable
63-L2700/E13
Upgrading of a VICAMATIC-2 unit for incorporating a graphic printer into the head. Test settings and results are plotted both as numerical and graphical format including penetration depth/time diagram. The upgrading shall be factory installed
63-L2700/E14
Needle for final setting test to EN
63-L2700/E15
Cylindrical probe for consistency test
63-L2700/E16
Additional weight 700 g
63-L2700/E18
Conical penetration probe 8 mm dia x 50 mm complete with 100g calibrated weight for gypsum testing to EN 13279
63-L0027/E9
Water thermostatic unit for VICAMATIC -2. Up to 2 units may be connected. 230 V, 50-60 Hz, 1 ph
63-L0027/E9Z
Water thermostatic unit for VICAMATIC -2. Up to 2 units may be connected. 110 V, 60 Hz, 1 ph
82-SW/VS
VICASOFT-PREMIUM software for PC connection of up to 32 VICAMATIC-2 units including remote control of each unit, data acquisition - processing - filing, printout of test reports.
Communication via LAN port (each VICAMATIC-2 unit is supplied complete with LAN cable). The connection of one VICAMATIC-2 unit is direct via the PC LAN-port, for more VICAMATIC-2 units (up to 32) one or more LAN hubs are required with total number of ports equal (or bigger) to the number of VICAMATIC-2 units included in the network. LAN hubs are not included
SPARE PARTS
63-L2700/E20
1,13 mm dia. needle for initial setting time test to EN
63-L2700/E21
1 mm dia. needle for setting time test to ASTM/AASHTO
63-L0027/E22
Plastic mould to EN
63-L0027/E23
Plastic mould to ASTM/AASHTO
63-L2700/E24
Glass base plate
63-L2700/E25
Spare base plate for in-water testing kit