Specification
|
Flexar
LC Autosampler
|
Flexar Peltier
LC Autosampler
|
Flexar FX
UHPLC Autosampler
|
Pressure limits
|
Up to 6100 psi (428 bar)
|
Up to 6100 psi (428 bar)
|
Up to 15,000 psi (1,034 bar)
|
Injection modes
|
Fixed Loop: 5x sample overfill
Partial Fill: Variable injection volumes
μL Pickup: Injections without any excess sample waste
|
Fixed Loop: 5x sample overfill
Partial Fill: Variable injection volumes
μL Pickup: Injections without any excess sample waste
|
Fixed Loop: 5x sample overfill
Partial Fill: Variable injection volumes
μL Pickup: Injections without any excess sample waste
|
Injection volume
|
Fixed Loop mode: 2 μL to 500 μL, depending on loop volume
Partial Fill mode: 0.1 μL to 2.45 Ml (up to half loop volume)
μL Pickup mode (no sample waste): 1 μL to (loop volume – 3x needle/tube volume)/2 Note: standard needle/tube volume is 15 μL
|
Fixed Loop mode: 2 μL to 500 μL, depending on loop volume
Partial Fill mode: 0.1 μL to 2.45 Ml (up to half loop volume)
μL Pickup mode (no sample waste): 1 μL to (loop volume – 3x needle/tube volume)/2 Note: standard needle/tube volume is 15 μL
|
Fixed Loop mode: 2 μL to 500 μL, depending on loop volume
Partial Fill mode: 0.1 μL to 2.45 Ml (up to half loop volume)
μL Pickup mode (no sample waste): 1 μL to (loop volume – 3x needle/tube volume)/2 Note: standard needle/tube volume is 15 μL
|
Injection cycle time
|
As fast as 8 seconds in Partial Fill mode or 35 seconds in μL Pickup mode
|
As fast as 8 seconds in Partial Fill mode or 35 seconds in μL Pickup mode
|
As fast as 8 seconds in Partial Fill mode or 35 seconds in μL Pickup mode
|
Loop volumes
|
2 μL to 5 mL, 100 μL standard
|
2 μL to 5 mL, 100 μL standard
|
2 μL to 5 mL, 50 μL standard
|
Sample/flush syringes
|
100, 250, 500, 1000 and 2500 μL; 250 μL standard
|
100, 250, 500, 1000 and 2500 μL; 250 μL standard
|
100, 250, 500, 1000 and 2500 μL; 250 μL standard
|
Injection repeatability
|
Fixed loop mode: 0.3% RSD
Partial loop mode: 0.5% RSD for ≥5 μL injections, 1.0% RSD for 1-4 μL injections
μL Pickup mode: 0.5% RSD for ≥5 μL injections, 1.5% RSD for 1 μL injection
|
Fixed loop mode: 0.3% RSD
Partial loop mode: 0.5% RSD for ≥5 μL injections, 1.0% RSD for 1-4 μL injections
μL Pickup mode: 0.5% RSD for ≥5 μL injections, 1.5% RSD for 1 μL injection
|
Fixed loop mode: 0.3% RSD
Partial loop mode: 0.5% RSD for ≥5 μL injections, 1.0% RSD for 1-4 μL injections
μL Pickup mode: 0.5% RSD for ≥5 μL injections, 1.5% RSD for 1 μL injection
|
Sample carryover
|
<0.01%, using programmable needle wash
|
<0.01%, using programmable needle wash
|
<0.01%, using programmable needle wash
|
Sample capacity
|
2 x 96-well high (deep) and low (shallow) microtiter plates; 100 2 mL vials; 200 0.2 mL vials; 25 6 mL vials
|
2 x 96-well high (deep) and low (shallow) microtiter plates; 100 2 mL vials; 200 0.2 mL vials; 25 6 mL vials
|
2 x 96-well high (deep) and low (shallow) microtiter plates; 100 2 mL vials; 200 0.2 mL vials; 25 6 mL vials
|
Derivatization/serial dilution
|
Both automated pre-column derivatization and serial dilution are supported using liquid mixing.
|
Both automated pre-column derivatization and serial dilution are supported using liquid mixing.
|
Both automated pre-column derivatization and serial dilution are supported using liquid mixing.
|
Injections per vial/plate
|
Limited only by sample volume and injection mode
|
Limited only by sample volume and injection mode
|
Limited only by sample volume and injection mode
|
Wetted materials in contact w/sample
|
316 SS, Vespel™, Tefzel™
|
316 SS, Vespel™, Tefzel™
|
316 SS, Vespel™, Tefzel™
|
Needle washes/flushes
|
Programmable: up to 9 each of pre- and post-injection and between-method needle washes/flushes. All washes are followed by air drying of needle via built-in air compressor
|
Programmable: up to 9 each of pre- and post-injection and between-method needle washes/flushes. All washes are followed by air drying of needle via built-in air compressor
|
Programmable: up to 9 each of pre- and post-injection and between-method needle washes/flushes. All washes are followed by air drying of needle via built-in air compressor
|
Peltier options
|
Cooling-only and Cooling/Heating options available
|
Cooling-only and Cooling/Heating options available
|
Cooling-only and Cooling/Heating options available
|
Peltier temperature range
|
Cooling-Only: 4 °C to ambient -3 °C (will reach 4 °C ±2 °C with ambient temperature up to 25 °C at relative humidity of 80%). Cooling/Heating: 4 °C to 40 °C (will reach 4 °C ±2 °C with Injection start synchronized to start pump program).
|
Cooling-Only: 4 °C to ambient -3 °C (will reach 4 °C ±2 °C with ambient temperature up to 25 °C at relative humidity of 80%). Cooling/Heating: 4 °C to 40 °C (will reach 4 °C ±2 °C with Injection start synchronized to start pump program).
|
Cooling-Only: 4 °C to ambient -3 °C (will reach 4 °C ±2 °C with ambient temperature up to 25 °C at relative humidity of 80%). Cooling/Heating: 4 °C to 40 °C (will reach 4 °C ±2 °C with Injection start synchronized to start pump program).
|
Audible noise level
|
LeAq <70 dB
|
LeAq <70 dB
|
LeAq <70 dB
|
Working temperature
|
10 °C to 40 °C (indoor use only)
|
10 °C to 40 °C (indoor use only)
|
10 °C to 40 °C (indoor use only)
|
Storage temperature
|
-25 °C to 60 °C
|
-25 °C to 60 °C
|
-25 °C to 60 °C
|
Humidity
|
20% to 80% RH, non-condensing
|
20% to 80% RH, non-condensing
|
20% to 80% RH, non-condensing
|
Safety and EMC compatibility
|
According to EC directives; CSA (UL) approved
|
According to EC directives; CSA (UL) approved
|
According to EC directives; CSA (UL) approved
|
Power requirements
|
95-245 VAC, 50/60 Hz (±1%), 200 VA maximum power consumption
|
95-245 VAC, 50/60 Hz (±1%), 200 VA maximum power consumption
|
95-245 VAC, 50/60 Hz (±1%), 200 VA maximum power consumption
|
Viscosity range
|
0.1-5 cP
|
0.1-5 cP
|
0.1-5 cP
|
Service Manager
|
Autosampler setup and troubleshooting using dedicated user interface
|
Autosampler setup and troubleshooting using dedicated user interface
|
Autosampler setup and troubleshooting using dedicated user interface
|
CDS system environments supported
|
TotalChrom® and Chromera®
|
TotalChrom® and Chromera®
|
TotalChrom® and Chromera®
|